Introduction

In modern microgrids, reliable and adaptive protection schemes are essential to ensure system stability during internal faults and dynamic operating conditions. Traditional inverse-time overcurrent (ITOC) protection often struggles to maintain coordination between protection levels when switching between grid-connected and islanded modes, resulting in delayed fault clearance and reduced reliability. To overcome these limitations, an improved inverse-time overcurrent protection scheme based on a composite parameter protection factor is proposed. This method integrates voltage and current phase relationships with voltage sag severity to enhance responsiveness and selectivity. By embedding both phase-difference and voltage-sag acceleration factors, the scheme ensures rapid and coordinated protection operation, improving overall fault management and stability in complex microgrid environments.

Problem Statement in Traditional ITOC Schemes

Traditional ITOC protection schemes primarily rely on current magnitude to detect and isolate faults. However, in microgrids operating with variable configurations—especially during transitions between grid-connected and islanded modes—the short-circuit current levels vary significantly. This variation leads to inconsistent tripping times, poor sensitivity, and loss of coordination among protection levels. As renewable and distributed energy sources increase, these issues become more prominent, demanding an adaptive and intelligent solution that considers multiple system parameters beyond current magnitude alone.

Composite Parameter Protection Factor Concept

The proposed scheme introduces a composite parameter protection factor (CPPF) that combines the phase relationship between the positive-sequence voltage fault component at the bus and the positive-sequence current fault component in the feeder, alongside the degree of voltage sag at the bus. This integrated approach captures both the electrical and dynamic characteristics of the fault, allowing for faster and more accurate fault detection. The CPPF thus provides a more reliable basis for protection decision-making in variable operational modes.

4. Design of Phase-Difference and Voltage-Sag Acceleration Factors
The novel protection method incorporates two acceleration factors: the phase-difference acceleration factor and the voltage-sag acceleration factor. The phase-difference factor quantifies the angular separation between voltage and current components, reflecting the fault's electrical nature and proximity. Meanwhile, the voltage-sag factor assesses the extent of voltage drop, representing the fault's severity. Together, these parameters dynamically adjust the tripping time, ensuring faster response for severe and nearby faults while preserving selectivity for distant or minor faults.

Coordination Between Protection Levels

By leveraging the proportional relationship between the composite parameter protection factor and the fault location, coordination among protection levels is optimized. This approach allows upstream and downstream relays to adapt their tripping characteristics in real time based on system conditions, avoiding unnecessary disconnections and maintaining selective isolation. Consequently, the proposed scheme enhances fault discrimination, reduces false tripping, and ensures continuity of power supply in microgrids with distributed energy sources.

Simulation and Performance Evaluation

The effectiveness of the proposed improved inverse-time overcurrent protection scheme was validated through simulations conducted using PSCAD/EMTDC. Various fault conditions—such as phase-to-phase and phase-to-ground faults—were modeled in both grid-connected and islanded modes. Results demonstrated that the new scheme significantly reduces tripping times and improves coordination compared to traditional ITOC methods. This confirms the scheme’s suitability for modern microgrids, where adaptability, speed, and coordination are critical for safe and efficient operation.

Global Particle Physics Excellence Awards


Get Connected Here:................ Twitter: x.com/awards48084 Blogger: www.blogger.com/u/1/blog/posts/7940800766768661614?pli=1 Pinterest: in.pinterest.com/particlephysics196/_created/ Tumbler: www.tumblr.com/blog/particle196

Hashtags

#Sciencefather, #Reseacherawards, #InverseTimeProtection, #MicrogridProtection, #CompositeParameter, #SmartGrid, #VoltageSag, #PhaseDifference, #ProtectionCoordination, #PSCAD, #OvercurrentProtection, #RenewableIntegration, #GridConnectedMode, #IslandedMode, #AdaptiveProtection, #FaultDetection, #PowerSystemReliability, #ShortCircuitAnalysis, #ElectricalEngineering, #ProtectionScheme, #ResearchInnovation,